Page 1 - User’s Manual

LTL 730 Dynamometer and Crane Scale User’s Manual Cooper Instruments and Systems PH: 540-349-4746 • FAX: 540-347-4755 www.cooperinstruments.com

Page 2 - CF 150 LTL 730 ii 5/16/06

CF 150 LTL 730 7 12/08 Peak force and unit of measure on 2nd line 104.5 lbf 302.5 lbf Format #3 Live force value plus unit of measure on 1st line

Page 3 - CONTENTS

CF 150 LTL 730 8 12/08 Contr Press this key to adjust the contrast of the LCD display. Press the Up soft key to lighten the contrast. Press the Dow

Page 4 - 2.0 SAFE OPERATION

CF 150 LTL 730 9 12/08 Comm The serial test is an internally conducted diagnostic that requires a jumper across transmit and receive. This requires

Page 5 - 2.1 Radio Safety

CF 150 LTL 730 10 12/08 7.1 Configuration Menu Figure 7. Configuration menu Config Setup The first soft key is Setup. Press this and you access the

Page 6 - 3.0 INTRODUCTION

CF 150 LTL 730 11 12/08 2. Press COM 2 or COM 1. COM2 is used to configure the optional radio board, if installed. The following display appears.

Page 7 - 4.4 Communicator Keys

CF 150 LTL 730 12 12/08 6. Select a databit value using the Sel keys to toggle between the two choices; 7 or 8 (default). Press Enter to accept t

Page 8 - Communicator Connectors

CF 150 LTL 730 13 12/08 2. Select a display mode value using the Sel key to scroll through the choices. Press Enter to accept the displayed setting

Page 9 - 6.0 LTL 730 SETUP

CF 150 LTL 730 14 12/08 The following screen is displayed: Select Yes if you only want the instrument to automatically shut down when there is ina

Page 10 - Setup Misc

CF 150 LTL 730 15 12/08 8.3 Force Measurement Rezero Rezeroing allows the weight or load of fixturing to be invisible to the measurement. The zeroed

Page 11 - Setup Test

CF 150 LTL 730 16 12/08 9.0 COMMUNICATOR OPERATION Use the UP and DOWN arrow keys on the Communicator to scroll through the displays of all active

Page 12 - 7.0 CONFIGURATION

CF 150 LTL 730 ii 5/16/06

Page 13 - 7.1 Configuration Menu

CF 150 LTL 730 17 12/08 Figure 9. Setup menu 9.2 Setup Menu Ptfmt Select from print formats 1-7. See Print Formats section on the following pages.

Page 14 - CF 150 LTL 730 11 12/08

CF 150 LTL 730 18 12/08 Test Lets you test the following items: Batt Press this to check the battery condition. Display shows voltage condition o

Page 15 - Config Mode

CF 150 LTL 730 19 12/08 Units Press this key to set the following: Choice of power-up unit of measure Enable or disable lbf, kgf, N, custom unit 1

Page 16 - Config Power

CF 150 LTL 730 20 12/08 Example: Cell<tab>Description<tab>Live Force<tab>Units<CR> 1<tab>North<tab>104.5<tab&

Page 17 - 8.0 LTL 730 OPERATION

CF 150 LTL 730 21 12/08 Many things can degrade radio signals, such as brick walls, metal reinforced concrete, machinery and even wiring within wal

Page 18 - 8.4 Displaying Peak Force

CF 150 LTL 730 22 12/08 A punch sized slightly smaller than the holes in the spacer may be helpful. The spacers should “sandwich” the dynamometer bo

Page 19 - 9.0 COMMUNICATOR OPERATION

CF 150 LTL 730 23 12/08 Key Settings (LTL 730 2): COM1 Trans Level – Disabled COM2 Trans Level – RF Radio Channel (1-64): 1 (must match Communicato

Page 20 - 9.2 Setup Menu

CF 150 LTL 730 24 12/08 Problem Possible Cause Solution system straight. Verify system is applying force directly through the dynamometer with no

Page 21 - 9.3 Config Menu

CF 150 LTL 730 25 12/08 14.2 Alignment Insure shackles are oriented parallel with the instrument. Apply load in the center of the shackle bow. 14.3

Page 22 - CF 150 LTL 730 19 12/08

CF 150 LTL 730 26 12/08 15.0 Warranty Repair Policy Limited Warranty on Products Any Cooper Instruments product which, under normal operating co

Page 23 - 10.0 GENERAL INFORMATION

CF 150 LTL 730 iii 5/16/06 CONTENTS 1.0 Specifications ...

Page 24 - 10.5 Installing Spacers

CF 150 LTL 730 1 12/08 1.0 SPECIFICATIONS Dynamometer Specifications Enclosure: Designed to NEMA4X/IP55. Suitable for continuous outdoor use. Accura

Page 25 - 11.0 COMMON CONFIGURATIONS

CF 150 LTL 730 2 12/08 Any zeroed deadload must be considered as part of the ultimate load. Although this instrument has a substantial overload p

Page 26 - 13.0 TROUBLESHOOTING

CF 150 LTL 730 3 12/08 Radio systems are vulnerable to interference, resulting in delays between the dynamometer scale and remote. In some instances

Page 27 - 14.1 Load Centering

CF 150 LTL 730 4 12/08 Zero key Use this key to zero the force indicated on the display. ESC key Use this key to escape from portions of the menu

Page 28 - CF 150 LTL 730 25 12/08

CF 150 LTL 730 5 12/08 Display Mode key Use this key to cycle between Communicator display modes. They are LTL 730 specific force value, LTL 730 sp

Page 29 - 15.0 Warranty Repair Policy

CF 150 LTL 730 6 12/08 6.0 LTL 730 SETUP To begin using the LTL 730, it is recommended that you set it up to suit your specific needs and equipment

Commentaires sur ces manuels